brp_errcode brp_VHL_GetFileInfo | ( | brp_protocol | protocol, |
unsigned | Id, | ||
unsigned * | Len, | ||
unsigned * | BlockSize | ||
) |
This command returns the available size of the VHL-file whose ID is specified by the ID parameter.
Two values are returned: the length of the VHL-file (Len) and the size of a single block (BlockSize).
The size of the returned value Len indicates the maximum number of bytes which can be read/written with the brp_VHL_Read() or brp_VHL_Write() commands. Attempting to read or write a larger amount of Bytes with brp_VHL_Read() or brp_VHL_Write() will generate an error status code (BRP_VHL_ErrRead or::BRP_VHL_ErrWrite ).
If the card system organizes its memory in blocks, BlockSize returns the size of a single block. If the memory is not organized in blocks, 1 will be returned. 0 will be returned if the block sizes are not unique (currently, there is no such card system in existence).
This command can only be executed if a card is selected, e.g. with a previous call of brp_VHL_Select() .
The returned VHL-file size corresponds to the reader's configuration values. It does not necessarily guarantee that a file of the returned sized can be read on the card. In some cases, the actual size of the card may be smaller than the returned VHL-file size.
[in] | protocol | used to execute the command |
[in] | Id | ID of VHL-file in configuration memory (starting at 0). To keep your application ConfigEditor compatible do not hardcode this ID in your application, but resolve it from a name via brp_VHL_ResolveFilename() . |
[out] | Len | Size of VHL-file in bytes. |
[out] | BlockSize | Size of a single block. |