DHWCtrl.DataflashWrite
Write data to a certain page.
Properties
- Command code: 0xE025
- Command timeout: 100 ms
- Possible status codes: General status codes, DHWCtrl.ErrDataflashTimeout, DHWCtrl.ErrDataflashVerify, DHWCtrl.ErrDataflashParam, DHWCtrl.ErrDataflashSpi, DHWCtrl.ErrDataflashFlash
Parameters (request frame)
Name | Type/Size | Description |
---|---|---|
Device | Integer (8 bits) | Flash device number. |
Mode | Integer (8 bits) | Writing mode. |
Page | Integer (16 bits) | Number of page to write to. |
StartAdr | Integer (16 bits) | Start address relative to page. |
Length of Data | Integer (16 bits) |
Length of Data in bytes |
Data | Raw data | Data to write to the Dataflash. |
Returned values (response frame)
None