CardEmu command group

This command group allows to emulate an ISO 14443-3 card.
WARNING: This command set is not available in all Baltech reader firmware variants.

Status codes

BRP status BRP Library Error Code Mnemonic Description
0x01 0x4701 (18177) CardEmu.CardemuErrNoTag No tag error.
0x02 0x4702 (18178) CardEmu.CardemuErrCollision Collision occurred (status value will be stored with bit position of collision in high nibble).
0x04 0x4704 (18180) CardEmu.CardemuErrHf General HF error.
0x07 0x4707 (18183) CardEmu.CardemuErrFrame Bit error, parity error or frame error (start /stop bit).
0x08 0x4708 (18184) CardEmu.CardemuErrCrc CRC checksum error.
0x10 0x4710 (18192) CardEmu.CardemuErrCom Communication error uC - reader chip.
0x11 0x4711 (18193) CardEmu.CardemuErrBuflen Remaining data in FIFO / FIFO overflow.
0x3F 0x473F (18239) CardEmu.CardemuErrTimeout Timeout occurred while waiting for card / APDU command.