EM.Login4469
Login to a EM4469/4569 tag with data has to match block 1.
Properties
- Command code: 0x311B
- Command timeout: 100 ms
- Possible status codes: General status codes, EM.ErrEmNoTag, EM.ErrEmRxdata, EM.ErrEmChecksum, EM.ErrEmParity, EM.EmCmdError, EM.EmTagtypeNotDetected, EM.ErrEmOvTo
Parameters (request frame)
Name | Type/Size | Description |
---|---|---|
Password | Integer (32 bits) | Password. |
Returned values (response frame)
None