Iso15.StayQuiet

This command puts a label into the quiet-state. This command shall always be executed in addressed mode (see the Iso15.SetMode command). After executing this command, the label will not response to any Iso15.GetUIDList command until its state machine is reset (either by a physical HF-reset (i.e. switching off the field of the antenna or taking the label out of the field) or by executing the commands Iso15.ResetToReady or Iso15.SetMode (using selected mode).

Properties

Parameters (request frame)

None

Returned values (response frame)

None