Mif.AuthE2
This command authenticates a certain sector of a card using a key from the secure EEPROM of the Baltech reader chip.
Depending on the value of the AuthMode variable, either key A or key B of the sector specified by the Block variable will be compared to the key specified in KeyIdx.
It is only possible to authenticate one sector at a time.
Properties
- Command code: 0x1004
- Command timeout: 100 ms
- Possible status codes: General status codes, Mif.ErrNoTag, Mif.ErrBitcount, Mif.ErrBytecount, Mif.ErrAuth, Mif.ErrKey, Mif.ErrCode
Parameters (request frame)
| Name | Type/Size | Description | |
|---|---|---|---|
| AuthMode | Enumeration (8 bits) |
Authentication Mode.
Values (2):
|
|
| Block | Integer (8 bits) | Block to authenticate. | |
| KeyIdx | Integer (8 bits) | Index of key in EEPROM which shall be used for authentication (range: 0 to 31). | |
Returned values (response frame)
None