Sys.SetRegister
Sets one or multiple of the reader's internal registers.
To reset a register, its Value should be set to 0xFFFF.
If the parameter ResetRegister is set to True , all registers of the reader will be reset.
Register setting operations are usually performed by changing the relevant configuration values.
Properties
- Command code: 0x000F
- Command timeout: 100 ms
- Possible status codes: General status codes, Sys.ErrRegAccess
Parameters (request frame)
Name | Type/Size | Description | |
---|---|---|---|
ResetRegister | Boolean (8 bits) | - | |
Length of RegisterAssignments | Integer (8 bits) |
Number of elements in the RegisterAssignments array
|
|
RegisterAssignments | Array | - | |
ID | Integer (16 bits) | ID of register to set | |
Value | Integer (16 bits) | New value of register to set |
Returned values (response frame)
None