Sys.SetRegister
Sets one or multiple of the reader's internal registers.
To reset a register, its Value should be set to 0xFFFF.
If the parameter ResetRegister is set to True, all registers of the reader will be reset.
Register setting operations are usually performed by changing the relevant configuration values.
Properties
- Command code: 0x000F
- Command timeout: 100 ms
- Possible status codes: General status codes, Sys.ErrRegAccess
Parameters (request frame)
| Name | Type/Size | Description | |
|---|---|---|---|
| ResetRegister | Boolean (8 bits) | - | |
| Length of RegisterAssignments | Integer (8 bits) |
Number of elements in the RegisterAssignments array |
|
| RegisterAssignments | Array | - | |
| ID | Integer (16 bits) | ID of register to set | |
| Value | Integer (16 bits) | New value of register to set | |
Returned values (response frame)
None