ACCESS200 installation guide for configuration via Wired Upload (USB) or preconfigured readers

  • For configuration via ConfigCard or Wireless Upload (NFC), use the separate installation guide.
  • For potted readers, we highly recommend configuration via ConfigCard or Wireless Upload. If you do want to use Wired Upload, make sure you follow the workflow for potted readers.

Equipment & requirements

  • Printed installation quick guide
  • Printed drill template

  • ACCESS200 reader including base part

    Check dimensions

    Drawing ACCESS200 with dimensions

    Dimensions in mm. Tolerance +/- 1 mm. Drawing not to scale.


    For more technical data, please see our hardware specification.

    Which base parts are available?

    You can choose between 2 base versions that differ in depth:

    Base version Depth Purpose Total reader depth including front
    Standard 12 mm Mount on a single gang box 14 mm
    Wall mount 19 mm Mount directly on the wall 21 mm

    Installation steps are the same for both base versions.

  • 3mm diameter countersunk head screws (to fix the base part)

  • Project card (to test reader and configuration)
  • Optional: AdrCard (to set bus address), LicenseCard (to deploy Prox license)
  • To deploy the configuration, see equipment and requirements here

Installation of unpotted readers

  1. Deploy configuration

    • Connect the reader to the laptop using the USB cable.
    • Deploy the configuration.
    • Once upload is completed, disconnect the USB cable.
  2. Fix base part

    • Fix the base part with the 3 mm diameter countersunk head screws.
    • Heads must not stand out more than 1 mm from the base surface.
  3. Wire reader

    Do not close the housing yet if you want to set a bus address (see next step).

  4. Optional: Set bus address

  5. Close housing

    • Plug the wired clamp back on the reader and fit the reader on the base.
    • If you need to reopen the housing, follow these instructions to avoid damage.
  6. Optional: Deploy Prox license

  7. Test reader and configuration

    • Test the readers with a project card. The host system must be configured for live operations.

Installation of potted readers

  1. Fix base part

    • Fix the base part with the 3 mm diameter countersunk head screws.
    • Heads must not stand out more than 1 mm from the base surface.

    For outdoor keypad readers, make sure you avoid rain interference.

  2. Wire reader

    • Connect the reader to the host system. To do so, cut the connector off the pigtail cable, shorten the cable, and strip the wires.
    • Connect a cut-open USB cable to the laptop.
    • Connect the USB cable to the USB wires of the pigtail cable (pins 5,6, and 9 as shown in the connector and pin specification).
  3. Deploy configuration

  4. Optional: Set bus address

  5. Close housing

    • Fit the reader on the base.
    • If you need to reopen the housing, follow these instructions to avoid damage.
  6. Optional: Deploy Prox license

  7. Test reader and configuration

    • Test the readers with a project card. The host system must be configured for live operations.